Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Int Endod J ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38411495

RESUMEN

AIM: To evaluate the indication of the endodontic treatment for vital intact teeth with the root apex involved in large radicular cystic lesions of endodontic origin. METHODOLOGY: This prospective cohort study enrolled healthy participants with radicular cysts of endodontic origin and with the root apex of vital intact teeth involved in the bone defect, as determined by cone beam computed tomography (CBCT). Thirty-two sound vital teeth were analysed by thermal (TPT) and electric pulp tests (EPT) before surgery (T0) and 1 week (T1), 2 weeks (T2), 3 months (T3) and 6 months (T4) post-surgery. Student's t-test (p < .05) was used to compare the EPT values at baseline and T4. anova (p < .05) was used to analyse the EPT variations for all maxillary and mandibular teeth. McNemar test (p < .05) was used to compare the results according to variation in EPT values gathering by variation, no variation and no response. RESULTS: At T1, 75 and 65.7% of teeth responded positively whilst 25 and 34.3% did not respond to EPT and TPT, respectively. The variation of the EPT values between T0 and T1 was observed for 50.0% of teeth, whilst no variation was noticed in 25.0% of teeth. At T4, 90.6 and 87.5% of teeth responded positively whilst 9.4 and 12.5% did not respond to EPT and TPT, respectively. At T4, variation of the EPT values between T0 and T4 was observed for 28.1%, whilst no variation was noticed in 62.5% of teeth. There were no statistical differences in EPT results between T0 and T4 (p > .05), but significant differences were observed for EPT values between T1 and T4 (p < .05), and between mandibular and maxillary teeth. The pulp sensibility of maxillary teeth worsened after surgery, before reverting progressively to T0 values, whilst no statistically significant differences were observed for mandibular teeth at the different time points. CONCLUSIONS: These data support the inconsistence of the prophylactic endodontic treatment in healthy vital teeth with apex involvement in large cystic lesions of endodontic origin. Post-surgery follow-up with TPT and EPT is recommended to assess pulp status.

2.
Eur J Dent Educ ; 2023 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-37715540

RESUMEN

INTRODUCTION: Computer simulations are stimulating increased attention in dentistry. Augmented reality superimposes a virtual scenario over an existing reality and allows interaction with it. Virtual reality (VR) simulates a fully immersive situation permitting the user to experience the full environment in real time. Haptic technology provides tactile and realistic force feedback for the user to experience the immersive situation as if they were really there. Preclinical training is important to gain familiarity with difficult surgical techniques and to implement interpersonal skills. Developing a valid assessment of surgical simulation is challenging. This paper wants to present a newly realized VR simulation in endodontic microsurgery through the developmental digital workflow, the demonstration of a haptic VR scenario and student self-assessment and self-reflection feedback. METHODS: The volumes were exported in a stereolithography format to prepare and optimize in terms of shape and shade for the VR simulation. The graphics and touchable haptic solid were created using Virteasy Editor, which allows the transformation of 3D surfaces into graphical and volumetric haptic solids depending on their material (enamel, dentine, pulp and bone). Users were asked to execute the osteotomy and root-resection preparation. The assessment criteria were determined, and the feedback statements were created by a questionnaire with fixed answers. Objective and qualitative criteria for assessing the preparation were obtained from the literature. RESULTS: This study provides proof that it is possible to provide reliable and clinically relevant qualitative feedback with a VR simulator. CONCLUSION: VR simulation offers an innovative approach with all the benefits of clinical experience. It permits you to save your own progress and review the assessment at any time.

3.
J Clin Med ; 12(18)2023 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-37762786

RESUMEN

(1) Background: A Dynamic Navigation System (DNS) is an innovative tool that facilitates the management of complex endodontic cases. Despite the number of advantages and limitations of this approach, there is no evidence-based information about its efficiency in comparison with that of the traditional method in endodontics. (2) Objectives: We aimed to explore any beneficial effects of the DNS and compare the outcomes of DNS vs. free-hand (FH) approaches for non-surgical and microsurgical endodontics. (3) Methods: A literature search was conducted in August 2023 to identify randomized, experimental, non-surgical, and microsurgical endodontic studies that compared the DNS with FH approaches. The procedural time (ΔT, s), substance loss (ΔV, mm3), angular deviation (ΔAD, °), coronal/platform linear deviation (ΔLD_C, mm), and apical linear deviation (ΔLD_A, mm) were recorded and analyzed. Quality and risk of bias assessments were conducted according to the Quality Assessment Tool For In Vitro Studies. A meta-analysis was performed using mean difference and standard deviation for each outcome, and heterogeneity (I2) was estimated. p < 0.05 was considered significant. (4) Results: One-hundred and forty-six studies were identified following duplicate removal, and nine were included in the systematic review and meta-analysis. The overall risk of bias was classified as low. The DNS was found to be more accurate and efficient than the FH approach was, resulting in a significantly shorter operation time (p < 0.00001) and less angular (p ≤ 0.0001) and linear deviation (p ≤ 0.01). For substance loss, the advantage of the DNS was significant only for microsurgery (p = 0.65, and p < 0.005, for non-surgical and microsurgical procedures, respectively). A reduced risk of iatrogenic failure using the DNS was observed for both expert and novice operators. (5) Conclusions: The DNS appears beneficial for non-surgical and microsurgical endodontics, regardless of the operator's experience. However, appropriate training and experience are necessary to access the full advantages offered by the DNS.

4.
Int J Prosthodont ; 36(5): 603-611, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33625400

RESUMEN

PURPOSE: To evaluate the fracture strength of endodontically treated molars filled with different composite resins with vs without fiber reinforcement. MATERIALS AND METHODS: A total of 60 intact mandibular molars were selected and endodontically treated. A standardized mesio-occlusal-distal cavity was prepared with cervical margins 1 mm above the cementoenamel junction and oral and buccal walls with 1.5-mm thickness. Universal adhesive was used in all specimens in etch-and-rinse mode. Specimens were divided into four groups (n = 15 each) according to restoration technique: group CSM = adhesive overlay with hybrid ceramic; group EXP = direct restoration with short fiber-reinforced composite; group ESU = direct restoration with nanohybrid composite; and group EST = direct restoration with nanohybrid composite reinforced with horizontal bidirectional glass fibers placed over the pulpal chamber floor. After 7 days of storage in water, samples were loaded until fracture using a universal testing machine. The maximum breaking loads were recorded in Newtons, and statistical analysis was then conducted with two-way ANOVA and post hoc Tukey test. Fragments were analyzed using scanning electron microscopy. RESULTS: Mean fracture resistance values were: CSM = 1,428.91 ± 316.90 N; EXP = 1,874.57 ± 299.47 N; ESU = 1,557.44 ± 355.65 N; and EST = 1,870.27 ± 145.11 N. The CSM and EXP groups showed the highest strength values when compared to the other groups. The variable fiber insertion did not significantly alter the fracture resistance. The origin of the fracture was always located on the occlusal surface, mainly in the major contact loading area. CONCLUSION: The use of fiber-reinforced composite showed great improvement in fracture resistance, similar to a cuspal coverage restoration. However, only short fiber-reinforced composites showed a favorable fracture pattern. Int J Prosthodont 2023;36:603-611.


Asunto(s)
Fracturas de los Dientes , Diente no Vital , Humanos , Resistencia Flexional , Fracturas de los Dientes/prevención & control , Diente no Vital/terapia , Cementos Dentales , Resinas Compuestas , Diente Molar , Análisis del Estrés Dental , Ensayo de Materiales , Restauración Dental Permanente
5.
Int J Prosthodont ; 36(5): 595-602, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-33871486

RESUMEN

PURPOSE: To evaluate the effect of three different curing protocols based on different ratios of self-curing and light-curing periods on the bond strength and nanoleakage of fiber posts luted with dual-curing self-adhesive cements. MATERIALS AND METHODS: A total of 48 single-root teeth were endodontically treated and obturated, and an 8-mm post space was prepared with dedicated drills. Specimens were randomly divided into two groups according to the self-adhesive cement employed: group 1 (G1) = PANAVIA SA Plus (Kuraray Noritake), and group 2 (G2) = Bifix SE (VOCO). The specimens were further divided into three subgroups (n = 8 each) according to the light-curing protocol applied: no light-curing (SG1), 20 seconds of light-curing 20 seconds after cement injection (SG2), and 20 seconds of light-curing 120 seconds after cement injection (SG3). Slices of 1-mm thickness were prepared for the pushout test and nanoleakage analyses of the coronal and apical regions after 24 hours of storage in artificial saliva. Results were statistically analyzed with three-way ANOVA and Tukey post hoc tests. Statistical significance was set for P < .05. RESULTS: Three-way ANOVA analysis showed that the factors of cement (P = .02) and curing protocol (P < .001) had a significant influence on bond strength. Tukey post hoc test reported that light-curing 120 seconds after injection showed higher bond strength compared to both no light-curing and photoactivation after 20 seconds. CONCLUSION: To achieve the highest bond strength with self-adhesive cements, photoactivation with a 120-second delay after mixing is required. There is no difference between light-curing immediately and light-curing 20 seconds after mixing.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Cementos de Resina/química , Recubrimiento Dental Adhesivo/métodos , Análisis del Estrés Dental , Ensayo de Materiales , Dentina
6.
Aust Endod J ; 49 Suppl 1: 107-112, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36281895

RESUMEN

This study investigated variation in working length during multiple-visit endodontic treatment. Patients (N = 106) with pulpitis or pulp necrosis, with or without apical periodontitis, were included. During the first appointment, glide path was performed with ProGlider and shaping with ProTaper Next. Working length was detected four times. Working length was then re-recorded prior to filling during the second appointment and a 0.5 mm threshold was selected as the minimum clinically meaningful variation. A logistic regression model was used to evaluate the impact of tooth anatomy, preoperative pulp status, apical periodontitis and lesions of endodontic origin on working length variation. Working length varied between first and second appointments in 34% of patients. The presence of apical periodontitis was the only variable significantly associated with variation in working length (p = 0.011). These data suggest that working length should be re-checked prior to root canal filling to prevent procedural errors.


Asunto(s)
Periodontitis Periapical , Pulpitis , Humanos , Preparación del Conducto Radicular , Cavidad Pulpar/anatomía & histología , Ápice del Diente/anatomía & histología , Periodontitis Periapical/terapia
7.
BMC Oral Health ; 22(1): 482, 2022 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-36357901

RESUMEN

BACKGROUND: Endodontic ledge (EL) formation is the most common complication of endodontic treatment. Although various etiological factors have been identified, canal curvature is the most significant variable correlated with EL formation. The aim of this micro-computed tomographic (micro-CT) study was to evaluate EL position in the mesial canals of the lower molars in relation to the degree of canal curvature. METHODS: Forty intact mandibular first molars with independent mesial canals with 20°-40° primary mesio-distal curvature, 10°-30° buccal-lingual canal curvature and 4 < r ≤ 8 mm main curvature radius were selected. Working length was measured with a K-File #10 and a high resolution pre-operative micro-CT analysis was performed. Ledges were created at the point of maximum canal curvature using stainless steel K-Files #30-35, alternating irrigation with 5% NaOCl and 10% EDTA. A post-operative high-resolution micro-CT analysis was then completed. Pre- and post-operative images were analyzed. The angle (α) formed between the vector passing through the geometric center of the EL and the center of the original canal lumen and the line joining the centers of the mesio-buccal and mesio-lingual canal orifices was calculated, and a descriptive statistical analysis was achieved. The α angle values were analyzed in relation to canal curvature using Kruskal-Wallis and post hoc Dunn's tests. The level of significance was set at P < 0.05. RESULTS: The α angles appeared inversely proportional to canal curvatures in the buccal-lingual and mesio-distal projections. The mean α angle was 36.4° (standard deviation 10.64; 95% confidence interval 34.1-40.9). CONCLUSION: Within the limitations of this study, endodontic ledges develop in the opposite direction to the three-dimensional canal curvature and their position is influenced by the degree of curvature. Clinically, the α angle values may be related to the recommended direction to manage endodontic ledges.


Asunto(s)
Cavidad Pulpar , Diente Molar , Humanos , Cavidad Pulpar/diagnóstico por imagen , Cavidad Pulpar/cirugía , Diente Molar/diagnóstico por imagen , Microtomografía por Rayos X/métodos , Preparación del Conducto Radicular/efectos adversos , Preparación del Conducto Radicular/métodos
8.
J Clin Med ; 11(15)2022 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-35956222

RESUMEN

The aim of this study was to compare the shaping ability of a modified ProTaper Next technique (PTNm) with that of TruNatomy (TN) in lower molars mesial curved canals using micro-computed tomography (Micro-CT). Sixty mesial canals of first mandibular molars were randomly assigned between two groups (n = 30). After canal scouting with K-File #10, glide path and shaping were carried out with TN or PTNm systems. The PTNm sequence consists of ProGlider, followed by ProTaper Next X1 and apical finishing with NiTiFlex #25 up to working length (WL) to ensure adequate apical cleaning. Samples were scanned using micro-CT and pre- and post-shaping volumes were matched to analyse geometric parameters: the volume of removed dentin; the difference of canal surface; centroid shift, minimum and maximum root canal diameters; cross-sectional areas; the ratio of diameter ratios (RDR) and the ratio of cross-sectional areas (RA). Measurements were assessed 2 mm from the apex and in relation to the middle and coronal root canal thirds. Data were analysed using ANOVA (p < 0.05). No statistically significant differences were found between the groups for any parameter at each level of analysis, except for RA at the coronal level (p = 0.037). The PTNm system showed the tendency to enlarge more in the coronal portion with a lower centroid shift at apical level compared with TN sequence (p > 0.05). Both PTNm and TN sequences demonstrated similar maintenance of original anatomy during the shaping of lower molar mesial curved canals.

9.
Biomedicines ; 10(7)2022 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-35884986

RESUMEN

The present study aimed to evaluate the wear rate of polymer-infiltrated network composites and ceramics against enamel in a bruxism-simulated scenario. Ninety-six (n = 96) molars were divided into six groups (n = 16) according to their occlusal material: group 1-a polymer-infiltrated network ceramic (PINC); group 2-a second polymer-infiltrated network ceramic (PINC2); group 3-nanohybrid resin-based composite (CO); group 4-cubic zirconia (ZR); group 5-lithium disilicate (LS); and group 6-sound enamel (EN). A laser scanner was used to digitalize all of the occlusal surfaces before and after a fatigue test, which was conducted with a chewing simulator set at 80 N and semicircular movement in order to simulate bruxist movement and loads. Statistical analysis of volume loss was performed with a one-way ANOVA and post hoc Bonferroni test. ZR had significantly inferior wear to PINC (p ≤ 0.01) and CO (p = 0.04). LS wore the antagonist enamel significantly more than PINC, CO, PINC2 and EN (p ≤ 0.01). On the other hand, ZR wore the antagonist enamel significantly more than CO (p ≤ 0.01) and PINC2 (p = 0.05). In conclusion, PINCs better preserved antagonist enamel at the expense of a higher wear of their own. LS causes significantly higher enamel wear compared with PINCs. ZR caused significantly higher enamel wear compared with CO and PINC2, but it was wear-resistant.

10.
J Clin Med ; 11(6)2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35329976

RESUMEN

The aim was to evaluate the antibacterial efficacy and penetration depth into dentinal tubules of a solution of chitosan nanodroplets (NDs) loaded with Benzalkonium Chloride (BAK). Seventy-two human single-root teeth with fully formed apex were used. Cylindrical root dentin blocks were longitudinally sectioned and enlarged to a size of a Gates Glidden drill #4. After sterilization, root canals were infected with Enterococcus faecalis ATCC 29212 and further incubated for three weeks. Specimens were assigned to three experimental groups (n = 20), plus positive (n = 6) and negative (n = 6) controls. In the first group, irrigation was achieved with 2 mL of NDs solution loaded with BAK (NDs-BAK), in the second with 2 mL of 5% sodium hypochlorite (NaOCl) and in the last with 2 mL of 2% chlorhexidine (CHX). Specimens were rinsed and vertically fractured. Confocal laser scanning microscopy (CLSM) and viability staining were used to analyze the proportions of dead and live bacteria quantitatively. The volume ratio of red fluorescence (dead) was calculated in 3D reconstructions. Data were analyzed by one-way ANOVA and post hoc Bonferroni tests (p < 0.05). The ratio of red fluorescence over the whole green/red fluorescence resulted in a significant comparison of NDs-BAK with NaOCl (p < 0.01) and NaOCl with CHX (p < 0.01). No differences were found between NDs-BAK and CHX (p > 0.05). The mean depth of efficacy was, respectively: NDs-BAK 325.25 µm, NaOCl 273.36 µm and CHX 246.78 µm with no statistical differences between groups. The NaOCl solution showed the highest antimicrobial efficacy, but nanodroplets with BAK seemed to have the same effect as CHX with a high depth of efficacy.

11.
Dent Mater ; 38(4): e94-e107, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35219524

RESUMEN

OBJECTIVES: To evaluate shear stress (SS) and normal pressure (NP) at the tooth-restoration interface of highly-filled flowable resin composite applied to deep margin elevation technique through FEM analysis generated by a microCT scan. METHODS: A reference maxillary molar with two class II cavities was prepared according to deep margin elevation protocol. A geometrical model was segmented from a micro-CT scan generating separate volumes of enamel, dentin and restorative materials. The 3D Finite Element (FE) model was subsequently built-up and an axial chewing load was simulated. Data concerning the tooth-restoration interface were analyzed in terms of SS and NP. Different materials and techniques were tested in order to evaluate the effects of the restorative material, the usage of a highly-filled flowable composite as liner and the substrate of the cervical area. RESULTS: Both SS and NP presented similar distribution, but showed significant differences between tested materials. Composites showed more homogeneous behavior in stress distribution compared to ceramic. The use of a highly-filled flowable composite as liner on the cervical margin significantly reduced SS and NP on the cavity floor and the cervical margin area. Lastly, stress distribution in the cavity floor area varied according to the cervical margin substrate: enamel showed a protective role in stress distribution. SIGNIFICANCE: Highly-filled flowable resin composites showed encouraging results when applied to deep margin elevation from an interfacial mechanical point of view. Further studies are needed to validate these data and to better define the role of cervical enamel in stress distribution.


Asunto(s)
Resinas Compuestas , Restauración Dental Permanente , Preparación de la Cavidad Dental , Materiales Dentales , Restauración Dental Permanente/métodos , Ensayo de Materiales , Microtomografía por Rayos X
12.
Odontology ; 110(1): 54-61, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34173078

RESUMEN

The shaping outcomes after instrumentation with rotary and reciprocating glide path and shaping systems were evaluated through micro-computed tomography (Micro-CT). Thirty extracted maxillary first molars were selected. Mesio-buccal canals were randomized into two groups (n = 15): rotary system ProGlider and ProTaper Next X1, X2 (PG-PTN) and reciprocating system WaveOne Gold Glider and WaveOne Gold Primary (WOGG-WOG). Specimens were micro-CT scanned before, after glide path and after shaping. Increase in canal volume and surface area, percentage of removed dentin from the inner curvature, centroid shift and canal geometry variation through ratio of diameter ratios (RDR) and ratio of cross-sectional areas (RA) were measured in the apical and coronal levels and at the point of maximum curvature. The number of pecking motions needed to reach the working length (WL) was recorded. One-way ANOVA and post hoc Turkey-Kramer tests were used (p < 0.05). Post-glide path analysis revealed that in the coronal third, RDR was more favorable to PG and centroid shift was lower for WOGG in the apical third. Post-shaping analysis showed a reduced removal of dentin and a more favorable RA for PTN at point of maximum curvature. The number of pecking motions up to WL resulted in different between groups both for glide path and shaping phases. Despite a higher dentin removal for reciprocating instruments at the point of maximum curvature, both systems seemed to produce well-centered glide path and shaping outcomes. Rotary and reciprocating systems seemed able to respect the original canal anatomy.


Asunto(s)
Diente Molar , Preparación del Conducto Radicular , Cavidad Pulpar , Diseño de Equipo , Oro , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Microtomografía por Rayos X
13.
J Clin Med ; 10(19)2021 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-34640531

RESUMEN

This meta-analysis aimed to evaluate postoperative pain (POP) following root canal filling (RCF) with gutta-percha/bioceramic sealer (BCS) vs. gutta-percha/traditional sealer (TS) techniques. Electronic databases were searched for randomized trials. Subgroup analyses were performed for analgesic intake, flare-ups, postoperative time (24/48 h), pulp status, and retreatment. The search yielded 682 records, and nine studies were selected. BCS was associated with significantly lower POP vs. TS at 24 h (P = 0.04) and 48 h (P = 0.0005). In addition, non-significant trends favoring BCS for analgesic intake at 24 h (P = 0.14), flare-ups (P = 0.24) and obturation techniques at 24 h (P = 0.41) and 48 h (P = 0.33), non-significant trends for lower POP with TS vs. BCS 24 h and 48 h in vital teeth (P = 0.50, P = 0.18, respectively), and for lower POP with BCS vs. TS in non-vital teeth at 24 h and 48 h (P = 0.16, P = 0.84, respectively). POP was numerically lower with TS vs. BCS at 24 h (P = 0.65) and 48 h after retreatment (P = 0.59). Moreover, POP did not vary between fillers when the treatment was over single (P = 0.28) or multiple visits (P = 0.50). BCS was associated with significantly lower short-term POP, and with a trend for lower analgesic intake and flare-up incidence, as compared to TS.

14.
J Adhes Dent ; 23(5): 421-428, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34549925

RESUMEN

PURPOSE: To three-dimensionally evaluate the interfacial gap of bulk-fill resin composites applied in deep Class-I restorations with different layering techniques and curing modes. MATERIALS AND METHODS: Ninety-six (n = 96) samples were prepared with standardized deep Class-I cavities and adhesive procedures. Four materials were tested: SDR (SDR), SonicFill2 (SF), Admira Fusion X-Tra (AFXT), Filtek Supreme XTE (FS). Four subgroups (n = 6) were created according to layering and curing techniques: 2+2mm increments with soft start curing (SG1), 2+2 mm with conventional curing (SG2), a 4-mm increment with soft start curing (SG3), a 4-mm increment with conventional curing (SG4). All samples underwent micro-CT scans; afterwards, voids surrounding the restorations automatically underwent a thresholding procedure (Mimics, Materialise; Geomagic Studio 12, 3D Systems) to analyze the 3D interfacial gap. Statistical analysis was performed using three-way ANOVA with Tukey's test (significance p < 0.05). RESULTS: Statistically significant differences were reported between materials, layering techniques and their interaction. No statistically significant differences were reported for polymerisation mode. Bulk-fill materials showed average interfacial gap volumes ranging from 0.031 mm3 to 0.200 mm3, while FS showed volumes ranging from 0.416 mm3 to 1200 mm3. CONCLUSIONS: All bulk-fill materials performed statistically significantly better than did FS (p < 0.05), with no statistically significant differences between them. Curing mode did not influence interfacial gap volume in any group (p > 0.05), while bulk-filling vs layering influenced the volume of interfacial gaps only in the FS group, which performied better when incrementally applied. Regarding gap localisation, the floor of the cavity was the area with the highest likelihood of gaps in all samples.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Ensayo de Materiales , Polimerizacion , Microtomografía por Rayos X
15.
Angle Orthod ; 91(3): 343-348, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33476365

RESUMEN

OBJECTIVES: To measure the thickness homogeneity of Invisalign (Align Technology Inc, San José, Calif) aligners with micro-computed tomography (micro-CT) scans. MATERIALS AND METHODS: Starting from micro-CT scanning of 20 different aligners, multiplanar reconstructions were obtained. An orthodontist blinded about the study measured aligner thickness in different regions (molar, canine, incisor) and in different sites (gingival-buccal, buccal, occlusal, lingual, and gingival-lingual). To assess various thicknesses in different aligner sites and regions, the sample was stratified into subgroups and linear regression analysis was performed. RESULTS: Descriptive analysis showed that mean thickness of aligners in the incisor region ranged from 0.582 mm to 0.639 mm, in the canine region from 0.569 mm to 0.644 mm, and in the molar region from 0.566 mm to 0.634 mm. Student's t-tests showed no significant differences in the aligner thickness of different regions when data were stratified by different sites. Student's t-tests showed significant differences in thickness homogeneity for the molar region when the data were stratified by tooth (mean difference = 0.068 mm; 95% confidence interval, 0.009-0.126 mm; P = .024). CONCLUSIONS: Invisalign aligner thickness is characterized by small differences. The only significant difference was revealed in the molar region where thickness of the gingival-lingual edge is significantly thinner than that measured at the occlusal aspect. From a clinical perspective, the results of the present study could be considered to explain the reduced predictability of several orthodontic tooth movements in the molar region.


Asunto(s)
Aparatos Ortodóncicos Removibles , Humanos , Incisivo/diagnóstico por imagen , Diente Molar , Técnicas de Movimiento Dental , Microtomografía por Rayos X
16.
J Contemp Dent Pract ; 22(12): 1477-1482, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35656690

RESUMEN

AIM: The aim of the study was to achieve the endodontic treatment of a second maxillary molar with abnormal anatomy through cone-beam computed tomography (CBCT) analysis and three-dimensional (3D) printing. BACKGROUND: A patient arrived referring recurrent abscesses, spontaneous pain, and the difficulty to eat properly; a diagnosis of tooth necrosis was made. The periapical X-ray showed an abnormal anatomy of the tooth. CASE DESCRIPTION: The preoperative analysis of the tooth morphology was performed through CBCT analysis. The 3D scans were reconstructed through a dedicated software application (Mimics) to visualize the abnormal anatomy and detect the root canal morphology. Moreover, a 3D printed model was created to plan the clinical stage. Canal shaping was achieved with ProGlider and ProTaper Next techniques, and the root canal filling was performed with a carrier-based technique. CONCLUSION: The limits of this case were the low definition of the CBCT owned by the patient and the difficulties during the scouting of the canals due to the abnormal endodontic space complicated by narrow and flat canals. The software reconstruction allowed a 3D high-definition preclinical analysis of the tooth anatomy. CLINICAL SIGNIFICANCE: Both digital analysis and printed models based on CBCT scans seemed fundamental to preclinically understand the abnormal endodontic anatomy.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Atención Odontológica , Humanos , Diente Molar/diagnóstico por imagen , Diente Molar/cirugía , Impresión Tridimensional , Tratamiento del Conducto Radicular
17.
J Clin Med ; 9(12)2020 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-33276670

RESUMEN

The aim of this study was to evaluate the ability of a PIPS (photon-induced photoacoustic streaming) Er:YAG laser to reduce the root canal system bacterial count in vivo in comparison to the traditional irrigation technique. The post-operative patients' quality of life (QoL) after endodontic therapy was evaluated through a questionnaire. Fifty-four patients affected by pulp necrosis with or without apical periodontitis biofilm disease were selected for endodontic treatment and randomly assigned to Group A (n = 27) with traditional irrigation and Group B (n = 27), with PIPS irrigation applied according to the protocol. Shaping was performed with ProGlider and ProTaper Next, and irrigation was performed with 5% NaOCl and 10% EDTA. Intracanal samples for culture tests were collected before and after irrigation. The microbiological analysis was evaluated by the Kolmogorov-Smirnov normality and Mann-Whitney tests (p < 0.05). A self-assessment questionnaire was used to evaluate the QoL during the 7 days after treatment; differences were analysed with Student's t-test. Irrigation with the PIPS device was significantly effective in reducing bacterial counts, which were higher for facultative than obligate anaerobic strains, particularly for Gram-negative bacteria, without statistical significance (p > 0.05). There were no significant differences among the QoL indicators, except for the maximum pain (p = 0.02), eating difficulty (p = 0.03) and difficulty performing daily functions (p = 0.02) in the first few days post-treatment. PIPS may represent an aid to root canal disinfection not affecting the patients' QoL, particularly for the first day after treatment.

18.
J Adhes Dent ; 22(3): 249-254, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32435765

RESUMEN

PURPOSE: The management of complicated crown-root fractures is challenging for endodontic restoration. The present case describes a patient who sustained trauma to the maxillary right central incisor. MATERIALS AND METHODS: Clinical and radiographic examination showed a complicated crown-root fracture and incomplete root development with periapical radiolucency and inadequate endodontic treatment with overfilling. Orthograde retreatment with MTA apical closure combined with a microsurgical approach to remove of extruded material was performed. Coronal sealing was accomplished with a direct adhesive restoration and marginal relocation. RESULTS: A 5-year follow-up showed complete healing of the periapical lesion and correct preservation of function and esthetic parameters. CONCLUSION: A modern minimally invasive treatment protocol allows the maximum conservation of residual dental tissues.


Asunto(s)
Incisivo , Fracturas de los Dientes , Estudios de Seguimiento , Humanos
19.
J Adhes Dent ; 22(2): 215-224, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32322842

RESUMEN

PURPOSE: To evaluate interfacial gap and fracture resistance of endodontically treated maxillary premolars, restored with different glass-fiber reinforced materials. MATERIALS AND METHODS: Eighty-four extracted intact premolars were endodontically treated and MOD cavities prepared. Specimens were divided into 7 groups (n = 12 for each) as follows: sound teeth (G1); no restoration (G2); direct composite restoration with fiber-reinforced composite (everX Posterior GC) (G3); direct composite restoration (Filtek Supreme XTE, 3M Oral Care; "FSXTE") (G4); a horizontal layer of high-viscosity flowable composite (G-ænial Flow, GC) was placed on the pulp chamber floor, 10 mm x 3 mm glass fibers (everStick NET, GC) were inserted into the cavity (G5); same procedure as in group 5 except the direct restoration was made incrementally with FSXTE (3M Oral Care) (G6); composite overlays were placed (G7). Specimens were scanned with micro-CT to evaluate 3D interfacial gaps before and after chewing simulation using Mimics software to calculate voids between restoration and tooth (dentin and enamel). These data (in mm3) were collected for statistical analysis. Thereafter, specimens were loaded to fracture using a universal testing machine. Maximum breaking loads were recorded in Newton (N). The data obtained were analyzed using two-way ANOVA and post-hoc Tukey's test (p < 0.05). RESULTS: ANOVA showed that horizontal glass-fiber insertions statistically significantly reduced interfacial gaps after chewing simulation. No differences in fracture resistance were found between Filtek Supreme XTE and everX Posterior; moreover, glass-fiber insertion did not significantly improve fracture resistance in either case. Composite overlays achieved significantly better fracture toughness than did direct restorations. CONCLUSIONS: For the direct restoration of endodontically treated premolars, the insertion of glass fibers into direct composite restorations was unable to guarantee a significant increase in the fracture resistance or a significant change in the fracture pattern. However, it significantly reduced interfacial gap volume after cycling fatigue.


Asunto(s)
Fracturas de los Dientes , Diente no Vital , Diente Premolar , Dentina , Humanos , Programas Informáticos
20.
J Adhes Dent ; 21(4): 329-335, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31432047

RESUMEN

PURPOSE: To evaluate the immediate and aged bond strength and interfacial nanolaekage of different adhesives and protocols on dental elements prepared with diamond burs and Er:YAG laser. MATERIALS AND METHODS: Forty molar crowns were flattened and a standardized smear layer was created. Teeth were divided into two main groups according to the dentin cutting technique: 1. Er:YAG laser for 30 s at 30 Hz repetition rate, 250 mJ energy per pulse, and water spray irrigation set at level 8; and 2. diamond bur. Each group was then divided into subgroups according to the adhesive protocol: SG1: dentin etching for 15 s followed by universal adhesive application (All Bond Universal, Bisco); SG2: universal adhesive application (All Bond Universal); SG3: two-step self-etch adhesive application (Clearfil SE Bond 2, Kuraray Noritake); SG4: etching followed by 3-step etch-and-rinse adhesive application (Optibond FL, Kerr). After curing the adhesives, resin composite buildups of 4 mm were made and specimens were sectioned to obtain 1-mm-thick sticks in accordance with the µTBS test technique. Sticks were stressed to failure at baseline and after 6 months of storage in artificial saliva. Three teeth per group were prepared for nanoleakage interfacial analyses. Data were statistically analyzed with three-way ANOVA and Tukey's post-hoc test (p < 0.05). RESULTS: A significant difference in bond strengths was found for treatment, aging, and adhesive protocol. Nanoleakage analysis showed higher marginal infiltration in Er:YAG-treated groups both at baseline and after aging. CONCLUSIONS: Surfaces prepared with diamond burs presented higher bond strengths than did those prepared with Er:YAG laser. Adhesive protocols and aging could influence the adhesive-dentin interface. Further studies are necessary to validate the results obtained.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Cementos Dentales , Dentina , Cementos de Resina , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...